One or more physical disks have failed or have been removed in a disk group,
resulting in this disk group becoming degraded
. The data on the virtual disks is still accessible.
However, data may be lost if another physical disk in the same disk group
fails. The Recovery Guru Details area provides specific information you will
need as you follow the Recovery Steps.
|
1
|
If the physical disk was removed, there will not be an LED associated with
a failure. Check the Recovery Guru details panel for any physical disk
removal messages and replace any previously removed drives.
|
|
2
|
Locate all failed physical disks associated with this disk group (the
status LED on the failed physical disks may be amber flashing). The Recovery Guru
Details area also provides the location of the failed physical disks.
|
|
3
|
For each individual physical disk listed, check the
Service Action Allowed status in the Details area.
|
If...
|
Then...
|
|
Service Action Allowed is YES
|
Go to step 4.
|
|
Service Action Allowed is NO
|
Answer the following question:
Are there other problems being reported in the Summary Area?
- Yes - Fix these problems first and then return
to this procedure after clicking the Recheck button.
- No - Stop this procedure and contact your
technical support representative.
|
|
|
4
|
|
If...
|
Then...
|
|
You want to replace the failed physical disk with a new physical disk
|
- Remove the physical disk (its status LED may be amber flashing).
- Repeat steps 2 and 3 until you have removed all of the failed physical disks associated with this disk group, and then go to step 5.
|
|
You want to utilize an existing unassigned physical disk or the in-use hot spare to replace the failed disk in the disk group
|
- Click on the Modify tab and then select Replace Physical Disks.
- Under Failed and Missing Physical Disks, select the physical disk that you would like to replace
- Under Available replacement physical disks, select the physical disk that you would like to use to replace the failed or missing physical disk
- Click on Replace Physical Disk.
Result: If you choose an unassigned physical disk as a replacement, the affected virtual disks change to an Operation in
Progress icon (in the Disk groups
and virtual disks link) as
the rebuild/copyback operations take place. When
rebuild/copyback is completed, the virtual disks return to Optimal , and the hot spare physical disk returns to Standby.
If you choose the Hot Spare as a replacement for the failed or missing physical disk, the Hot Spare role will be changed to Assigned. A new Hot Spare would need to be assigned if that functionality is desired
- Repeat above steps for each failed physical disk
- Click the Recheck button to rerun the Recovery Guru
to ensure that the failure has been fixed.
|
|
|
5
|
Wait 30 seconds and then insert the new physical disks.
Notes:
- Data rebuild should begin on the new physical
disks. Their status LEDs and the activity indicator lights
of the physical disks in the disk group will start flashing.
- If you are replacing a physical disk in a storage array
that contains hot spares, data rebuild will start on the hot
spare before you insert the new physical disk. The data on the
replacement physical disk may not be rebuilt until after it has
completed the process on the hot spare.
|
If...
|
Then...
|
|
The data rebuild for all new physical disks does
NOT automatically start within a few minutes
|
Go to step 6.
|
|
The data rebuild for all new physical disks in the disk group is
complete
|
Go to step 7.
|
|
|
6
|
Perform the following steps on each replaced physical disk
to start a manual rebuild on the physical disk:
|
a
|
Open a Command Prompt, and type the following command:
SMcli -n <storageArray_name>;
where storageArray_name is the name of the storage array listed
in the Details area.
Note: If you receive an error from this command, change your
working directory to the directory that contains the SMcli executable.
|
|
b
|
Execute the following command to manually rebuild a physical disk in
a disk group:
start physicalDisk [enclosureID,
slotID] reconstruct;
where enclosure_ID is the enclosure ID for the enclosure where the
physical disk resides and slot_ID is the slot position within the
enclosure.
Notes:
- The commands above are case-sensitive, and must be
entered exactly as shown.
- When rebuild starts on a disk group, the icon
changes to Operation in Progress
in the Disk Groups and Virtual Disks dialog
(accessed from the Summary tab by clicking the Disk
groups & virtual disks link). When rebuild is
completed, the disk group becomes Optimal .
- Repeat this step for each physical disk that does not
rebuild automatically in the disk group. When data rebuild
for all physical disks in the disk group is complete, go to step 7.
|
|
|
7
|
Click the Recheck button to rerun the
Recovery Guru. The failure should no longer appear in the Summary area.
|