Autoconfigure Storage Array Hot Spares

This command automatically defines and configures the hot spares in a storage array. You can run this command at any time. This command provides the best hot spare coverage for a storage array.

Syntax

autoConfigure storageArray hotSpares

Parameters

None.

Notes

When you run the autoConfigure storageArray hotSpares command the RAID controller module firmware determines the number of hot spares to create based on the total number and type of physical disks in the storage array. For Fibre and SATA physical disks: firmware creates 1 hot spare for the storage array and 1additional hot spare for every 60 physical disks in the array. For PATA physical disks: firmware creates 1 hot spare for the storage array and 1 additional hot spare for every 20 physical disks in the array.

Minimum Firmware Level

6.10