Incompatible Physical Disk Due to Newer Configuration Database

What Caused the Problem?

A physical disk is incompatible for use in this storage array because it contains a newer configuration database than what is supported by the storage array. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.

Caution: Electronic discharge can damage sensitive components. Always use proper antistatic protection when handling components. Touching components without using a proper ground may damage the equipment.

Important Notes

Recovery Steps

1
If... Then...
You want to initialize this physical disk so that it can be used in this storage array Note: This option will erase all the data on the physical disk.

Go to step 2.

You want to keep or backup the data on this physical disk

OR

You want to replace this physical disk with a new physical disk

a Remove the physical disk.

Note: If you need to keep the data on the physical disk, you must reinsert the physical disk into the original storage array.

b If you are replacing the physical disk with a new physical disk, wait 30 seconds, then insert a new physical disk.

Its fault indicator light may be lit for a short time (one minute or less).

c Go to step 4.
2 Highlight the physical disk in the physical view of the Array Management Window (AMW), and then select the Advanced >> Recovery >> Initialize >> Physical Disk menu option.
3 Carefully read and follow all instructions in the Confirm Initialization dialog.  When the initialization operations completes, go to step 4.
4 Click Recheck to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your technical support representative.