Correcting a partially managed storage array condition for an out-of-band storage array

A partially managed storage array occurs when only one RAID controller module is defined or can be reached when the storage array is added to the MD Storage Manager Software or found by the MD Storage Manager Software.

The following conditions can cause a partially managed storage array that is managed using out-of-band connections:

Use this procedure to correct a partially managed storage array that is managed using out-of-band connections.

  1. Make sure all cables connected to the RAID controller module are not damaged.
  2. Make sure all cables are tightly connected.
  3. Make sure the IP addresses are correct for both RAID controller modules.
  4. Click New.
  5. Click Manual: from the Add New Storage Array dialog.
  6. On the Add New Storage Array - Manual dialog, enter the name or IP address of the RAID controller module that is not listed, and then click Add.