Download Storage Array Firmware/NVSRAM
This command downloads firmware and, optionally, NVSRAM values for the storage array RAID controller module. If you want to download only NVSRAM values, use the downLoad storageArray NVSRAM command.
Syntax
download storageArray firmware [, NVSRAM ] file="filename" [, "NVSRAM-filename"] [downgrade=(TRUE | FALSE)] [activateNow=(TRUE | FALSE)]
Parameters
Parameter Description NVSRAM
Include this parameter when you want to download a file with NVSRAM values when you download a firmware file. Do not include square brackets with this parameter. Include a comma after the term firmware. filename
The file path and name of the file containing the firmware. Valid filenames must end with a .dlp extension. Enclose the filename in double quotes (" "). NVSRAM-filename
The file path and name of the file containing the NVSRAM values. Valid filenames must end with a .dlp extension. Enclose the NVSRAM filename in double quotes (" "). Include a comma after the firmware filename. downgrade
Use this parameter if you are loading firmware that is a previous version. The default is FALSE. Set downgrade to TRUE if you want to download an earlier version of firmware. activateNow
Use this parameter to activate the firmware and NVSRAM images. The default is TRUE. If you set activateNow to FALSE, you must use the activate storageArray firmware command to activate the firmware and NVSRAM values at a later time. Minimum Firmware Level
5.00