??? Set Enclosure Service Action Allowed Indicator

Set Enclosure Service Action Allowed Indicator

This command turns on or turns off the Service Action Allowed indicator light on a power-fan module, an interconnect-battery module, or an environmental services monitor (EMM) module. If the storage array does not support the Service Action Allowed indicator light feature, this command returns an error. if the storage array supports the command but is unable to turn on or turn off the indicator light, this command returns an error.

Syntax

set enclosure [trayID] (powerFan [(left | right)] | interconnect | battery [(left | right)] | esm [(left | right)]) serviceAllowedIndicator=(on | off)

Parameters

Parameter Description
enclosure This parameter identifies the enclosure where the power-fan, interconnect-battery, or EMM module resides. Enclosure ID values are 0 to 99. Enclose the enclosure ID value in square brackets ([   ]). If you do not enter an enclosure ID value, the RAID controller module enclosure ID is the default.

powerFan

The parameter defines the power–fan module Service Action Allowed indicator light that you want to turn on or turn off. Valid power–fan module identifiers are left or right. (The values left and right are with respect to the front of the E6000 series command modules.) Enclose the power???fan module identifier in square brackets ([   ]).

interconnect This parameter defines the Service Action Allowed indicator light for the interconnect-battery module.
battery This parameter defines the Service Action Allowed indicator light for a battery.
esm This parameter defines the Service Action Allowed indicator light for an EMM module.

serviceAllowedIndicator

This parameter defines whether the Service Action Allowed indicator light is turned on or turned off. To turn on the Service Action Allowed indicator light, set this parameter to on. To turn off the Service Action Allowed indicator light, set this parameter to off.

Notes

This command was originally defined for use with the E6000 RAID controller module enclosure. This command is not supported by RAID controller module enclosures that were shipped before the introduction of the E6000 RAID controller module enclosure.

Minimum Firmware Level

6.14 adds the powerFan parameter and the interconnect parameter
6.16 adds the enclosure parameter and the esm parameter