Important: During the diagnostics, the
The Diagnostics option allows a user to verify that a RAID controller module is functioning properly, through the use of various internal tests.
The Diagnostics use a combination of three different tests: Read Test, Write Test, and Data Loopback Test. You should run all three tests at initial installation and any time there are changes to the
The Read Test initiates a read command as it would be sent over an I/O data path. It compares data with a known, specific data pattern, checking for data integrity and
A Write Test initiates a write command as it would be sent over an I/O data path (to the Diagnostics region on a specified physical disk). This Diagnostics region is then read and compared to a specific data pattern. If the write fails or the data compared is not correct, the RAID controller module is considered to be in error and is failed and placed offline. (Use the Recovery Guru to replace the RAID controller module.)
Important: The Data Loopback Test does not run on RAID controller modules that have SCSI connections between the RAID controller modules and physical disks.
The Data Loopback Test is run only on RAID controller modules that have
Notes:
Running RAID Controller Module Diagnostics