Correcting a partially managed storage array condition for an out-of-band storage array

A partially managed storage array occurs when only one controller is defined or can be reached when the storage array is added to the storage management software or found by the storage management software.

The following conditions can cause a partially managed storage array that is managed using out-of-band connections:

Use this procedure to correct a partially managed storage array that is managed using out-of-band connections.

  1. Make sure all cables connected to the controller are not damaged.
  2. Make sure all cables are tightly connected.
  3. Make sure the IP addresses are correct for both controllers.
  4. Click New.
  5. Click Manual: from the Add New Storage Array dialog.
  6. On the Add New Storage Array - Manual dialog, enter the name or IP address of the controller that is not listed, and then click Add.