Start Physical Disk Channel Fault Isolation Diagnostics
This command runs the physical disk channel fault isolation diagnostics and stores the results.
Syntax
start physicalDiskChannel [(1 | 2 | 3 | 4 | 5 | 6 | 7 | 8)] RAID controller module [(a | b)] faultDiagnostics {testDevices=[all | RAID controller module=(a | b) | esms=[trayID1 (left | right), ... trayIDn (left | right)] | physical disks=[trayID1, slotID1, ... , trayIDn, slotIDn]] | dataPattern=(fixed | pseudoRandom) | patternNumber=[(0xhexadecimal | integerLiteral)] | maxErrorCount=integer | testIterations=integer | timeout=timeInterval}
Parameters
Parameter Description RAID controller module
The identifier letter of the RAID controller module that you want to test. Valid RAID controller module identifier values are a or b, where a is the RAID controller module in slot A, and b is the RAID controller module in slot B.
testDevices
The identifiers of the devices (RAID controller modules, EMMs, or physical disks) that you want to test. You can specify all or enter the specific identifiers for the devices that you want to diagnose.
dataPattern
The method of repeatability that you want to test.
patternNumber
The hexadecimal data pattern you want to use to run the test. This number can be any hexadecimal number between 0000 to FFFF.
maxErrorCount
The number of errors that you want to accept before terminating the test.
testIterations
The number of times that you want to repeat the test.
timeout
The length of time in minutes that you want to run the test.
Notes
Use the save physicalDiskChannel faultDiagnostics command and the stop physicalDiskChannel faultDiagnostics command in association with the start physicalDiskChannel faultDiagnostics command. These commands are needed to save the diagnostic test results to a file and to stop the diagnostic test.
You can also stop this command at any time by pressing Ctrl+C.
Minimum Firmware Level
7.30