A memory consistency error was detected on a RAID controller module. The Recovery Guru Details area provides specific information you will need as you follow the recovery steps.
| If... | Then... |
| Your storage array has one RAID controller module | Go to "Procedure for Storage Arrays with One RAID Controller Module." |
| Your storage array has two RAID controller modules | If there are any hosts connected to this storage array that are NOT running a host-based, multi-path failover driver, stop I/O to the storage array from each of these hosts.
Go to "Procedure for Storage Arrays with Two RAID Controller Modules." |
| 1 | From the RAID Controller Modules tab of the Storage Array Profile, check the replacement part number of the affected RAID controller module and ensure that you have a new RAID controller module with the same replacement part number.
If you do not have a RAID controller module with the appropriate replacement part number, contact your technical support representative. |
||||||
| 2 | Stop all I/O to this storage array. | ||||||
|
3 |
Turn off power to all power-fan modules in the enclosure containing the failed RAID controller module. |
||||||
| 4 | Remove the affected RAID controller module.
|
||||||
| 5 | Important: If the new RAID controller module module does NOT contain a battery, insert the battery from the old RAID controller module module into the new replacement RAID controller module module. Consult your hardware documentation for details.
Make sure at least 1 minute has elapsed. Then, insert the new (compatible) RAID controller module module firmly into place. |
||||||
| 6 | Turn on power to all power-fan modules in the enclosure.
Wait until all physical disks have completed the spin-up process, and then go to step 7. |
||||||
| 7 | From the RAID Controller Modules tab of the Storage Array Profile, check the status of the RAID controller module. The RAID controller module should have an optimal status. | ||||||
| 8 | Click the Recheck button to rerun the Recovery Guru. The failure should no longer appear in the Summary area. If the failure appears again, contact your technical support representative. |
| 1 | Place the affected RAID controller module offline.
|
||||||
| 2 | Read all of the following steps before taking any action.
|