If you have an in-band storage array, follow this procedure. Click Refresh after each step to make sure of the results.
Make sure that the is installed and running.
If you started the host before the host was connected to the controllers in the storage array, the host-agent software will
not be able to find the controllers. If so, make sure that the hardware connections are secure, and restart the host-agent
software.
Make sure that the network can access the by using the ping command. Use the form ping<host-name-or-IP-address>.
Examine the Ethernet cables to make sure that you cannot see any damage and that they are securely connected.
Make sure that the applicable network configuration tasks have been performed (for example, IP addresses have been assigned
to each controller).
Make sure that the controller firmware is compatible with the storage management software on your management station.
If the controller firmware was upgraded, the storage management software might not have access to the storage array. A new
version of storage management software might be needed to manage the storage array with the new version of the controller
firmware. If this problem exists, contact your Customer and Technical Support representative.
Look to see if there is too much network traffic to one or more controllers.
This problem corrects itself because the storage management software tries to re-establish communication with the controllers
in the storage array at regular times. If the storage array was unidentified and a subsequent try to connect to the storage
array succeeds, the storage array becomes responsive.
For an , look to see if management operations are taking place on the storage array from other storage management stations.
The type of management operations being performed and the number of management sessions taking place together establish the
number of connections made to a controller. When the maximum number of TCP/IP connections have been made, the controller stops responding.
This problem corrects itself because, after some TCP/IP connections complete, the controller then becomes responsive to other
connection tries.
If the storage array is still unidentified, problems might exist with the controllers. Contact your Customer and Technical
Support representative.